Copyright © 2023 Guangdong Tongwei Machinery Co., Ltd. All Rights Reserved.
Links | Sitemap | RSS | XML | Privacy PolicyTongwei is rich in experience as a manufacturer and supplier of 30 Ton Industrial Air Cooled Plastic Chiller in China with high credibility and excellent performance parameters, which can provide a wide range of plastic chiller from 1/2 Ton to 200 Ton cooling capacity in air-cooled ad water-cooled chiller. 30 Ton Industrial Air Cooled Plastic Chiller designed and manufactured by Tongwei is used in plastic industrial from 5℃ to 25 ℃. All industrial chiller units are with 12 months warranty time including free spare parts and full-time technical support and low cost of maintenance. We can provide high quality, competitive price and fast delivery time to you for all industrial chillers. We look forward to becoming your long-term industrial air cooled plastic chiller supplier in China. Chiller Model: TW-40AF Cooling Capacity: 113.58KW(97675 kcal/h) @ 50HZ / 132.89KW(114280kcal/h) @ 60HZ Refrigerant: R22/R407c/R410a/R134A/R404a Power Supply: 380V/50HZ /3PH (Standard) / 208-480V/60HZ/3PH(Customized) Compressor Brand: Panasonic/Danfoss Scroll Compressor Evaporator Type: Coil in SS Water Tank (Standard) / Shell and Tube(Customized)
Tongwei is a leading China 30 Ton Industrial Air Cooled Plastic Chiller manufacturers and suppliers. Industrial air cooled plastic chiller is one type of plastic chiller, which is refrigeration machine that control temperature by producing cooling and releasing heat by chilled air from the system, it no need install with water cooling tower for heat dissipation. It is used to cool down the plastic process equipment that is used to produce plastic products, such as plastic injection machine, plastic extruding machine, sheet extrusion machine or profile extrusion machine, bottle blowing machine and film blowing machine, to maximize productivity, extend lifetime of the machine and improve the quality.30 Ton industrial air cooled plastic chiller model TW-40AF with the cooling capacity is about 120KW(100000Kcal/h) .It includes FOUR scroll 10HP Panasonic /Danfoss compressor using environmental friendly R410A/R407C refrigerant, air-cooled condenser, condenser fins, SS coil in water tank heat exchanger, water pump,refrigeration circuit, expansion valve and protecting devices, temperature controller.
As a professional plastic chiller manufacturer and supplier for over 15 years, Tongwei is always happy to provide our free service and technical support accessible to our clients,so If you are planing to buy a high quality industrial air cooled plastic chiller suited to work for different processing to develop your business,Contact us to get a quote or clear a query about choosing plastic chiller at the best rates for your application.
Model |
TW-40AF |
||||
nominal cooling capacity |
KW |
50HZ |
113.58 |
||
60HZ |
132.89 |
||||
Ton |
50HZ |
32.36 |
|||
60HZ |
37.79 |
||||
Chilled Water temperature range |
℃ |
5~35 |
|||
Max power consumption |
kw |
37.1 |
|||
Full load |
Amp |
109 |
|||
power source |
|
3PH-380V-50HZ (Standard) 3PH-220-480V-60HZ (Customized) |
|||
refrigerant |
type |
|
R22/R407C/R410A/R134A |
||
control |
|
External balance of thermal expansion valve |
|||
compressor |
type |
|
hermetic scroll type |
||
power |
kw |
7.5*4 |
|||
QTY. |
Unit |
4 |
|||
condenser |
type |
|
Efficient aluminum finned copper sleeve+low noise external rotor fan |
||
air volume |
m3/h |
40000 |
|||
fan motor |
kw |
0.6*6 |
|||
evaporator |
type |
|
Coil in Water tank evaporator (Standard) shell and tube Type Evaporator (Customized) |
||
Cooling water flow rate |
m3/h |
19.53 |
|||
Tank volume |
L |
610 |
|||
inlet and outlet connection(BSP) |
inch |
3’’ |
|||
Water pump |
power |
kw |
4 |
||
Water Flow |
M3/h |
25 |
|||
Max.Pressure |
Bar |
2 |
|||
safety devices |
Compressor overheating protection,over-current protection,high and low pressure protection,over-temperature protection,traffic protection,phase sequence/phase loss protection,low level protection,frost protection |
||||
dimension |
mm |
2360*1360*2020 |
|||
weight |
kg |
1200 |
»Cooling capacity from 1/2 Ton to 200 Ton
»208-570V 60HZ 3Phase power supply customize for USA ,Philippines,Mexico,Peru Customers
»Industrial air cooled plastic chiller is with R22 ,R407c,R410a,R134a refrigerant for option .If you want chiller to install and work below 55℃ high ambient temperature with any high pressure alarm ,you can use the environmental friendly R134A refrigerant.
»High-quality scroll or screw compressor compressor
»SS coil in water tank,shell&tube or SS PHE evaporator for optional
The compressor is the key mover in Industrial air cooled plastic chiller because it produces pressure variations to stir the refrigerant around.
For 30 Ton Industrial Air Cooled Plastic Chiller, which is with FOUR unit 10HP Panasonic /Danfoss brand compressor, using R410A/R407C/R134a refrigerant,this brand compress is with high refrigeration efficiency,low noise ,energy saving,environmental protection and durability,safety and stability.
Panasonic Compressor
The evaporator is a crucial component of industrial air cooled plastic chiller , as it is responsible for extracting heat from the liquid being cooled,it is located between the compressor and the expansion valve. There are three types of evaporators : coil in water tank evaporator , shell and tube evaporator, 304SS stainless steel plate type evaporator.
Coil in SS Water Tank Evaporator
SS Plate Type+ Water Tank Evaporator
Shell and Tube Evaporator
The water pump is designed to increase the pressure and the flow of the chilled water in a closed space.
the water pressure water pump for chiller is about 2 bar , but if you need more higher water pressure , please tell us when you inquiry .For example ,when you use chillers for cooling bottle blowing machine ,the water pressure for water pump need about 4 bar .
Water Pump
High Pressure Water Pump
The condenser for industrial air cooled plastic chiller is equipped with efficient cross-seam fins and female threaded copper tubes for high heat exchange efficiency and good stability.Its function is to cool down the refrigerant steam released from the compressor into a liquid or gas-liquid mixture.
Aluminum fin+fan Condenser
Tongwei chillers use precision digital temperature controller, it RS485 communication port,which can do remote monitoring and control. Simple operation, low failure rate, high safety factor, easy installation.
Controller Panel
30Ton Air Chiller Built with Water Tank Inside Installation for Reference
30Ton Air Chiller with Buffer Water Tank Outside Installation for Reference
There are five important chiller specifications you need consider when you choose a chiller for your application :the cooling capacity for chiller ,the voltage required for operation, the associated pump horsepower and flow rate (contact us for custom selection), refrigerant, and the evaporator type.
One of the most frequently ask about how we can know the cooling capacity for chillers. We use KW ,Ton, But/h,Kcal/h to choose chiller cooling capacity :1 KW=860 kcal/h ; 1 TON=3.517 KW; 1 KW=3412 Btu/h;
There is also a formula to calculate the cooling capacity for chiller:.
Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-T2)/0.86
Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)
Oversize the chiller by 20% Ideal Size in KW = KW x 1.2
Noted : T1:Incoming Water Temperature (℃) T2:Required Chilled Water Temperature(℃)
For example, what size of chiller is required to cool 10m³ water from 35°c to 15 °c in 1 hour?
Temperature Differential = 35℃-15℃=20℃
Water Flow Rate = 10 m³/hour
Cooling Capacity in KW = 10 x 20 ÷ 0.86 = 232 KW
Oversize the chiller = 232 x 1.2 = 278.4KW
278.4 kw cooling capacity for chiller is required.
Different countries and regions have different standards for industrial electricity, the common power supplies are 208-230V, 380-420V,440-480V,50Hz or 60Hz, 3phase.
Such in Philippines ,the power supply is 220V 60HZ 3PH , 380V 60HZ 3PH ,460V 60HZ 3PH;
in Singapore and Malaysia ,the power supply is 415V 50HZ 3PH;
in Mexico ,the power supply is 220V 60HZ 3PH;
In USA ,the power supply is 208V 60HZ 3PH;575V 60HZ 3PH;480V 60HZ 3PH and so on
When you decide the capacity/tonnage of the chiller, we will recommend you the suitable pump in KW,which standard water pump is about 2 bar .If you need more high water pressure , please us when you inquiry.
R22, R410A, R407C, R404A, R134A are optional choices.
R22: good cooling effect, but R22 is considered a powerful greenhouse gas, so it’s forbidden in most countries.
R410A: eco-friendly, R-410A has replaced R-22 as the preferred refrigerant for use in residential and commercial air conditioners in Japan, Europe, and the United States. R-410A operates at higher pressures than other refrigerants.
R407C: a good replacement for R22, good cooling effect.
R404A: suitable for application that requires low temperature(below -10°c).
R134A: a non-flammable gas used primarily as a “high-temperature” refrigerant, suitable for air-cooled chiller working at a high ambient temperature above 50℃.
Chillers generally have two types of evaporators: one is coil in water tank evaporator ,the other one is shell and tube evaporator.
Coil and tank evaporator, which has a built-in water storage tank for more convenient use,so there’s no need for extra buffer tanks. This is also our standard evaporator for chiller , if you don’t have buffer tank ,we just use this evaporator for your chiller.
Shell and tube type evaporator, which requires an additional water buffer tank to connect .
As a professional industrial air cooled plastic chiller supplier &exporter,we have our own shipment forwarder to arrange the shipment .Our chiller machine is with plywood packing,which prevent damage during transportation and meet export standards.There are three ways can delivery your chiller unit :
1. Ship by Air: As the chiller is with compressor ,water pump and fans ,the compressed refrigerant and oil inside the compressor is a dangerous item with the possibility of explosion , so it needs to release the compressed refrigerant before transportation. (It means that water chiller without refrigerant when choosing this shipping way. After the machine arrives at your destination, you need to add refrigerant by local professionals. The airline company also request us to provide many documents to prove that the chiller not a dangerous product. The freight cost by air is very high may be higher than the cost of chiller , So By air for delivery is not the mode of transport recommended to our customer.
2. Ship by Sea: The transportation time is longer than by air , but the freight cost is cheap ,and there is no need to add refrigerant after the equipment arrives at the destination.This shipping way is the most suitable mode of transportation for you to delivery your local port.
3.If you have your own shipment container in your other supplier in China, we can help you delivery the chiller machine to your supplier in any city of China .
▪ Experience you can trust
We have been designing and building industrial process chiller for over 15 years. From air cooled chiller to water cooled chillers and everything in between, we have built chillers for nearly every industry and every application.
▪ Fast Quote
Get a quote for your project today! We typically provide a custom quote within 2 hours.
▪ 24/7 customer service
Believe that we will always be by your side. Whether you have a question or need a quote, there‘s always someone answering the phone 24 hours a day.
▪ Durable, reliable chiller machine & Competitive Price
Our products are manufactured from high quality materials and we offer a competitive warranty on all industrial chillers.