Links | Sitemap | RSS | XML | Privacy PolicyAs a leading industrial glycol chiller system manufacturer and supplier with over 15 years of experience, Tognwei provides a complete range of water-cooled screw glycol chillers from the TW-WSL series from 80KW to 1000KW and the chiller temperature control range from -30℃ to +5℃.Industrial glycol chiller system water cooled screw chiller is with SCREW compressor used R404a refrigerant ,shell and tube evaporator and condenser , Simenon PLC temperature controller, which is widely used in breweries, wineries, cider mills, and spirits, beverage, dairy milk, yogurt machine, laboratories, semiconductor, medical, pilot plants, and some other applications that require accurate and precise ultra-low temperature control. We have strict quality control and strong ability of designing and manufacturing .We look forward to becoming your long-term water-cooled glycol screw chiller supplier in China. Cooling Capacity: 30 Ton to 200 Ton Chilled Water Temperature :-30℃ to 5℃ Refrigerant: Environmental Friendly R404a Power Supply: 380V/50HZ /3PH (Standard) / 208-480V/60HZ/3PH(Customized) Compressor Brand: Hanbell/Bitzer Screw Compressor Evaporator Type: shell and tube
Industrial glycol chiller is a refrigeration-based cooling device that is used to provide cooling and maintain the temperature for efficient working of process by using chilled glycol as a refrigerant. The two types of ethylene glycol are ethylene glycol-based or propylene glycol-based. The antifreeze properties of ethylene glycol ensure that the coolant remains in a fluid state to reach its low cooling point.Glycol is recommended for all chiller units when operating temperatures are below 41°F (5°C). A glycol chiller unit consists of refrigeration components and pipes containing a glycol-water mixture as the coolant. The chilled fluid from the refrigeration unit is transported through pipes associated with the heat exchanger surrounding the heating process. After absorbing heat from the associated process, the heated coolant is returned to the refrigeration unit to be cooled, and the process is repeated
Industrial glycol chiller system water cooled screw chiller,also named industrial water cooled screw glycol chiller, is cooling capacity from 30 HP to 200HP ,with hanbell/Bizter screw compressor using environmental friendly R404a refrigerant,shell and tube evaporator /condenser,PLC controller,expansion valves ,without water tank and water pump.It need connect with cooling tower and cooling pump for heat dissipate.
As a leading industrial glycol chiller system manufacturer and supplier in China,not only do we provide high-quality chiller machines, but we prioritize excellent customer service. A major advantage of our Tongwei, is that our customers are our top priority, which sets us apart from our competitors. Our knowledgeable team is dedicated to providing excellent customer service and your satisfaction.Some of the key benefits our team provides for your chiller include:Thoroughly unpack, clean and test each chiller system before shipping; Conduct routine quality assurance checks on every unit; Only ship brand new machines and systems to our customers;Troubleshoot and resolve problems as promptly and efficiently as possible. If you are sourcing for high quality and optimal temperature-maintaining Industrial Glycol Chiller manufacturer in China,please feel free to contact us to customized your glycol cooling water systems with high quality and reasonable price for the low temperature chillers. We look forward to working with you.
TW-WSLSeries Water Cooled Glycol Chiller Techinical Parameters (One Compressor) | |||||||||||
Model Item | DNC-40WSL | DNC-50WSL | DNC-60WSL | DNC-70WSL | DNC-80WSL | DNC-90WSL | DNC-100WSL | DNC-120WSL | |||
Cooling capacity | -10℃ | KW | 72 | 93.8 | 102 | 124 | 136 | 161 | 186 | 222 | |
-20℃ | 48 | 63 | 69 | 84 | 92 | 108 | 125 | 149 | |||
-30℃ | 29.5 | 41.3 | 49 | 60 | 66 | 78 | 90 | 107 | |||
HP | 40HP | 50HP | 60HP | 70HP | 80HP | 90HP | 100HP | 120HP | |||
Input power | KW | 30 | 38 | 42 | 51 | 56 | 63 | 73 | 88 | ||
Max Current | A | 91 | 121 | 128 | 153 | 171 | 193 | 220 | 268 | ||
power source | 3PH-380V/415V-50HZ/60HZ(3PH~200V/220V~50HZ/60HZ) | ||||||||||
Refrigerant | Type | R22/R404A | |||||||||
Charging | kg | 28 | 36 | 43 | 50 | 58 | 65 | 72 | 86 | ||
Control | Thermostatic expansion valve | ||||||||||
Compressor | Type | Semi-hermetic screw | |||||||||
power | KW | 30 | 38 | 42 | 51 | 56 | 63 | 73 | 88 | ||
Start mode | Y-△ | ||||||||||
Capacity control | % | 0-25-50-75-100 | |||||||||
Evaporator | Type | TEMP. | Shell and tube | ||||||||
Coolant volume | -10℃ | m3/h | 12.4 | 16.1 | 17.5 | 21.3 | 23.4 | 27.7 | 32 | 38.2 | |
-20℃ | 8.3 | 10.8 | 11.9 | 14.4 | 15.8 | 18.6 | 21.5 | 25.6 | |||
-30℃ | 5.1 | 7.1 | 8.4 | 10.3 | 11.3 | 13.4 | 15.5 | 18.4 | |||
Water pressure drop | KPa | 32 | 35 | 38 | 42 | 42 | 45 | 40 | 43 | ||
Pipe connection | Inch | 3" | 3" | 3" | 3" | 4" | 4" | 4" | 5" | ||
Condenser | Type | shell and tube | |||||||||
Cooling water flow | m3/h | 25 | 32.3 | 35.5 | 43.3 | 47.5 | 60 | 65 | 77 | ||
Water pressure drop | KPa | 42 | 42 | 45 | 43 | 43 | 45 | 48 | 46 | ||
Pipe connection | Inch | 3" | 3" | 3" | 3" | 4" | 4" | 4" | 5" | ||
Safety devices | Compressor overheating protection,overcurrent protection,high and low pressure protection,overtemperature protection,traffic protection,phase sequence/phase loss protection,low level protection,anti-freezing protection. | ||||||||||
Dimension | Length | mm | 2500 | 2550 | 2600 | 2750 | 2800 | 2800 | 2900 | 3000 | |
Width | mm | 780 | 780 | 780 | 780 | 950 | 950 | 950 | 1200 | ||
Height | mm | 1650 | 1650 | 1650 | 1650 | 1800 | 1950 | 1950 | 1580 | ||
Net weight | kg | 920 | 1100 | 1250 | 1600 | 1850 | 1900 | 2100 | 2550 | ||
Running weight | kg | 1050 | 1260 | 1430 | 1850 | 2150 | 2200 | 2400 | 2750 | ||
Notes: 1.Rated cooling capacity is based on: the chilled water inlet and outlet temperature 12℃/ 7℃; cooling water inlet and outlet temperature 30℃/35℃. 2.Chilled water temperature range: -30℃to 30℃; chilled water inlet and out let temperature difference: 3℃to 8℃; cooling water temperature range: 18℃to 30℃; Cooling water temperature range: 18℃to 30℃; cooling water inlet and outlet temperature difference: 3.5℃to 10℃. |
▪ Siemens PLC temperature controller for overall monitoring of chiller running status; .
▪ water temperature range from -30℃ to 5 ℃
▪ High quality shell and tube condenser and heat exchanger
▪ Screw compressor with environmental friendly R404a refrigerant and four grade capacity control 25%-50%-75%-100%;
▪ It no need connect with water cooling tower and water cooling pump
▪Chiller equipped with the following safety protections:Overload Protection,Inverse Phase Alarm,High/Low Pressure Alarm,Water Flow,Water Level Indicator,Anti-Freeze Protection
The compressor is the key mover in Water Cooled Screw Glycol Chiller because it produces pressure variations to stir the refrigerant around.
For Industrial Glycol Chiller System Water Cooled Screw Chiller , which is with Hanbell Screw brand or Bizter Screw compressor for optional depends on the required refrigeration capacity, using R404A refrigerant,this brand compress is with high refrigeration efficiency,low noise ,energy saving,environmental protection and durability,safety and stability.
Each screw compressor with 4 steps of energy control 25%-50%-75%-100% to make sure the whole screw chiller is stable and guarantee high refrigeration performance.
Hanbell Screw Compressor
Bizter Screw Compressor
The evaporator is a crucial component of water cooled glycol chiller, as it is responsible for extracting heat from the liquid being cooled,it is located between the compressor and the expansion valve. Water Cooled Screw Chiller Uses highly efficient closed loop shell and tube type heat exchanger as the evaporator.
Shell and Tube Evaporator
The condenser for water cooled glycol chiller is water-cooed type shell and tube for high heat exchange efficiency and good stability.Its function is to cool down the refrigerant steam released from the compressor into a liquid or gas-liquid mixture.
Water-cooled type Shell and Tube Condenser
Tongwei chillers use Integrated PLC control system with human-computer interface and big LED touch screen panel.
4.Spare Part for Water-cooled Glycol Screw Chiller
There are two types of glycol chiller: one is air-cooled glycol chiller ,the other is water-cooled glycol chiller ;
Air-cooled glycol chillers use ambient air to dissipate heat from the processes. They are energy-efficient, space-saving, and less maintenance that helps save money.
Water-cooled glycol chillers use water from an external water cooling tower to dissipate heat from the processes. These systems are longer lifespan, Relatively quiet, and more consistent cooling performance than the air-cooled glycol chiller.
Glycol Scroll Chiller Glycol Screw Chiller
▪ 1hp-60HP Above 30HP
▪ Danfoss/Panasonic Scroll Compressor Hanbell/Bitzer Screw compressor
▪Built with water tank and water pump Without water tank and water pump
Air Cooled Glycol Scroll Chiller
Air Cooled Glycol Screw Chiller
Water Cooled Glycol Scroll Chiller
Water Cooled Glycol Screw Chiller
We know that once the temperature drops to 0°C or even lower, water will freeze. Glycol helps water prevent freezing and turn into ice. This is why we call it is glycol chiller.
Using a glycol-water mixture as a chiller coolant has various benefits over using clean water as a chiller coolant. These advantages are due to its unique physical properties, including a lower freezing point than water.
Generally speaking, a glycol chiller consists of refrigeration components and pipes containing a glycol-water mixture as the coolant. The chilled fluid from the refrigeration unit is transported through pipes associated with the heat exchanger surrounding the heating process. After absorbing heat from the associated process, the heated coolant is returned to the refrigeration unit to be cooled, and the process is repeated.
For many types of chillers, glycol is mixed with water in a 60/40 ratio. A high proportion of ethylene glycol significantly improves the antifreeze performance of the mixture. This is useful in situations where rapid cooling is required. In these cases, the process can be cooled to very low temperatures without freezing the coolant inside the pipes.
The working principle of traditional chillers is to transfer heat between two media: fluid and solid. These cooling systems work by absorbing heat or vapor compression. The basic components of a chiller system include the refrigeration unit and the piping system that circulates the refrigerated coolant.
Property |
Ethylene Glycol |
Propylene Glycol |
Freeze point depression |
More effective |
Less effective |
Heat transfer efficiency/capacity |
Better |
Less |
Viscosity |
Lower |
Higher |
Flammability |
Low |
Low |
Chemical Oxygen Demand |
Low |
Higher |
Biodegrading |
Degradesin 10-30 days |
Needs more than 20-30 days to degrade |
Carcinogenic |
No |
No |
Toxic |
High level of acute when taken orally, targets the kidneys
|
Lower level of acute
|
Skin Irritant |
Low |
Low |
Ethylene Gycol And Propylene Glycol
A glycol chiller is composed of a refrigeration component and tubing containing a water-glycol mixture as coolant. Chilled fluid from the refrigeration unit is channeled through the piping associated with a thermal exchanger surrounding a heated process. After absorbing heat from the associated process, the hot coolant is returned to the refrigeration unit for cooling after which the process is repeated.
A glycol chiller consists of a compressor, an evaporator, a condenser, a throttling element, and an electric control system. Let’s see what’s the working principle of a glycol chiller:
Tongwei glycol chiller uses top screw-type compressor features energy efficiency, low noise, and long service time.
In order to ensure that the pressure inside the evaporator is low enough and that the refrigerant is at such a low temperature, the compressor is used to pump out the evaporated refrigerant and compress the low temperature and pressure into the high temperature and pressure refrigerant gas.
Glycol chillers are designed and manufactured by Tongwei and feature a choice of air-cooled or water-cooled condensers.
The high-temperature and high-pressure refrigerant condenses into liquid in the condenser. The refrigerant in the condenser releases heat in the air or water that is cooler than it.
Thermal expansion valve plays an important role in industrial glycol chiller. The refrigerant of the glycol chiller is reduced from the condensation pressure to the evaporation pressure, so the liquid from the condenser can be put into the liquid tank.At this time, the refrigerant is at normal temperature and high pressure, and then passes through the expansion valve to lower the boiling point, and the liquid enters the evaporator to absorb heat and evaporate.
The evaporator for industrial air cooled screw glycol chiller just is: shell and tube type heat exchanger.
The low-temperature and low-pressure refrigerant liquid passes through the thermal expansion valve and exchanges with the evaporator.
Once the heat is absorbed, it becomes saturated or superheated steam that can be returned to the compressor for refrigeration.
It is important to use the proper ratio of glycol to water mixture in the cooling system depends on the coldest temperature you need during operation, as insufficient glycol can cause the system to freeze, possibly bursting pipes and even destroying the chiller evaporator even may damage the glycol chiller, while too much glycol to a chiller system will result in an inefficient system.
But what’s the best ratio for glycol and water mixtures? Please see below glycol ratio of glycol and water mixtures for the glycol chiller in your cooling process:
Glycol |
Water |
Water Temperature |
16% |
84% |
0℃ |
24% |
76% |
-5℃ |
32% |
68% |
-10℃ |
40% |
60% |
-15℃ |
45% |
55% |
-20℃ |
50% |
50% |
-25℃ |
55% |
45% |
-30℃ |
Glycol chiller is a specific kind of cooling system,which is used to cool a variety of liquids and other industrial applications.
By using a glycol chiller can achieve the low temperature for your industrial usage you need .
Glycol chillers are most used for below these Industries:
In breweries, the glycol chiller is used for cooling the wort,Controlling Fermentation,Crash Cooling Vessels,Prepackaging and Product Storage.
Glycol Chiller for Breweries
Glycol chillers are widely used in the fermentation process, cold stabilization and room cooling purposes.
Glycol Chiller for Wineries
Fermentation control needs critical water temperature control. Glycol chiller can provide cold chilling of the juice and milk, also the cold storage of the final product.
Glycol Chiller for Cider Mills
During the fermentation process, the glycol chiller will provide a steady coolant for circulation between distillation tanks & stills for heat removal purposes.
Glycol Chiller for Distilleries
Glycol chillers can provide low-temperature coolant to guarantee the safety and consistent quality of frozen foods, food processing companies need a low-temperature cooling day in and day out.
Glycol Chiller for Food Industry
A properly designed dairy glycol chiller can cool the milk very rapidly to help keep milk temperatures (and bacteria growth) under control as it is transferred from the milking parlor to its insulated tank.
Glycol Chiller for Dairy Product
Do you need a glycol chiller for an application not mentioned here? Contact us and we’ll customize an affordable solution for your exact demands.
There are four important chiller specifications you need consider when you choose a chiller for your application :the cooling capacity for chiller ,the voltage required for operation, the associated pump horsepower and flow rate (contact us for custom selection), refrigerant, and the evaporator type.
One of the most frequently ask about how we can know the cooling capacity for chillers. We use KW ,Ton, But/h,Kcal/h to choose chiller cooling capacity :1 KW=860 kcal/h ; 1 TON=3.517 KW;1 KW=3412 Btu/h;
There is also a formula to calculate the cooling capacity for chiller:.
Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-T2)/0.86
Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)
Oversize the chiller by 20% Ideal Size in KW = KW x 1.2
Noted : T1:Incoming Water Temperature (℃) T2:Required Chilled Water Temperature(℃)
For example, what size of chiller is required to cool 10m³ water from 35°c to 15 °c in 1 hour?
Temperature Differential = 35℃-15℃=20℃
Water Flow Rate = 10 m³/hour
Cooling Capacity in KW = 10 x 20 ÷ 0.86 = 232 KW
Oversize the chiller = 232 x 1.2 = 278.4KW
278.4 kw cooling capacity for chiller is required.
Different countries and regions have different standards for industrial electricity, the common power supplies are 208-230V, 380-420V,440-480V,50Hz or 60Hz, 3phase.
Such in Philippines ,the power supply is 220V 60HZ 3PH , 380V 60HZ 3PH ,460V 60HZ 3PH;
in Singapore and Malaysia ,the power supply is 415V 50HZ 3PH;
in Mexico ,the power supply is 220V 60HZ 3PH;
In USA ,the power supply is 208V 60HZ 3PH;575V 60HZ 3PH;480V 60HZ 3PH and so on
When you decide the capacity/tonnage of the chiller, we will recommend you the suitable pump in KW,which standard water pump is about 2 bar .If you need more high water pressure , please us when you inquiry.
R22, R410A, R407C, R404A, R134A are optional choices.
R22: good cooling effect, but R22 is considered a powerful greenhouse gas, so it’s forbidden in most countries.
R410A: eco-friendly, R-410A has replaced R-22 as the preferred refrigerant for use in residential and commercial air conditioners in Japan, Europe, and the United States. R-410A operates at higher pressures than other refrigerants.
R407C: a good replacement for R22, good cooling effect.
R404A: suitable for application that requires low temperature(below -10°c).
R134A: a non-flammable gas used primarily as a “high-temperature” refrigerant, suitable for air-cooled chiller working at a high ambient temperature above 50℃.
As a professional low temperature glycol chiller supplier &exporter,we have our own shipment forwarder to arrange the shipment .Our chiller machine is with plywood packing,which prevent damage during transportation and meet export standards.There are three ways can delivery your chiller unit :
1. Ship by Air: As the chiller is with compressor ,water pump and fans ,the compressed refrigerant and oil inside the compressor is a dangerous item with the possibility of explosion , so it needs to release the compressed refrigerant before transportation. (It means that water chiller without refrigerant when choosing this shipping way. After the machine arrives at your destination, you need to add refrigerant by local professionals. The airline company also request us to provide many documents to prove that the chiller not a dangerous product. The freight cost by air is very high may be higher than the cost of chiller , So By air for delivery is not the mode of transport recommended to our customer.
2. Ship by Sea: The transportation time is longer than by air , but the freight cost is cheap ,and there is no need to add refrigerant after the equipment arrives at the destination.This shipping way is the most suitable mode of transportation for you to delivery your local port.
3.If you have your own shipment container in your other supplier in China, we can help you delivery the chiller machine to your supplier in any city of China .
▪ Experience you can trust
We have been designing and building water chiller for over 15 years. From air cooled chiller to water cooled chillers and everything in between, we have built chillers for nearly every industry and every application.
▪ Fast Quote
Get a quote for your project today! We typically provide a custom quote within 2 hours.
▪ 24/7 customer service
Believe that we will always be by your side. Whether you have a question or need a quote, there‘s always someone answering the phone 24 hours a day.
▪ Durable and reliable machine
Our products are manufactured from high quality materials and we offer a competitive warranty on all industrial chillers.