Home > Products > Glycol Chiller > Air Cooled Glycol Scroll Chiller > Small Glycol Chiller For Distillery
Small Glycol Chiller For Distillery
  • Small Glycol Chiller For DistillerySmall Glycol Chiller For Distillery
  • Small Glycol Chiller For DistillerySmall Glycol Chiller For Distillery
  • Small Glycol Chiller For DistillerySmall Glycol Chiller For Distillery
  • Small Glycol Chiller For DistillerySmall Glycol Chiller For Distillery

Small Glycol Chiller For Distillery

Temperature control is a key factor for distilleries that produce premium products. As a professional and leading glycol chiller manufacturer and supplier ,Tongwei works carefully match the precise system to the exact requirements of our clients. We have been manufacturing small glycol chiller for distillery for many years we have refined our designs to create the best system for your needs today. Also, we offer full customization of Distillery Chillers to fit the demands of your customer base as your distillery grows. We look forward to becoming your long-term low temperature distillery chiller supplier in China.

Cooling Capacity: 1HP to 60HP
Chilled Water Temperature :-30℃ to 5℃
Refrigerant: Environmental Friendly R404a
Power Supply: 380V/50HZ /3PH (Standard) / 208-480V/60HZ/3PH(Customized)
Compressor Brand: Panasonic /Danfsoo Scroll Compressor
Evaporator Type: SS Plate Type (Standard) / Shell and Tube Customized)

Send Inquiry

Product Description


Small Glycol Chiller For Distillery

Glycol Chiller in Distillery ,also called distillery chillers is a special process chiller that used to cool a number of different distillation processes in the distillery industry.It uses a water and glycol mixture as a coolant which allows it to efficiently transfer heat and maintain temperature control in different processes: distillation columns, mash coolers, heat exchangers, fermentation tanks,dephlegmating, and other distillation processes.We offer packaged chillers, portable chillers, glycol chillers and other water cooling systems from 1/2 ton to 50 ton cooling capacity and control water temperature from -30℃ to 5 ℃ that keep the distillery processes cool. Now, we have installed many chillers in distillery where our experience and expertise are meeting the needs of distilleries around the world.


Small glycol chiller for distillery is designed and manufactured by Tongwei with specific components like the Panasonic/Danfoss compressor, air-cooled or water-cooled condenser, refrigerant water tank, glycol pump, stainless steel plate or shell and tube heat exchanger, control panel, expansion valves, and protecting devices, etc. For such low temperature glycol chiller ,it uses R404a refrigerant. The refrigerant is a non-depleting ozone gas and is considered environmentally friendly.


As a leading custom glycol chillers manufacturer and supplier in China,not only do we provide high-quality chiller machines, but we prioritize excellent customer service. A major advantage of our Tongwei, is that our customers are our top priority, which sets us apart from our competitors. Our knowledgeable team is dedicated to providing excellent customer service and your satisfaction.Some of the key benefits our team provides for your chiller include:Thoroughly unpack, clean and test each chiller system before shipping; Conduct routine quality assurance checks on every unit; Only ship brand new machines and systems to our customers;Troubleshoot and resolve problems as promptly and efficiently as possible.  If you are looking for a small low temperature glycol chiller, please feel free to contact us to customized your glycol cooling water systems with high quality and reasonable price for the low temperature chillers. A member of our team will be happy to address any questions you may have and discuss complete technical specifications. We look forward to working with you.

 


Small Glycol Chiller For Distillery Technical Specification

TW-AL Series Glycol Chiller  System Techinical Parameters
                                   Model            Item Temp. TW-3AL TW-5AL TW-6AL TW-8AL TW-10AL TW-12AL TW-15AL TW-20AL TW-25AL TW-30AL TW-40AL
Cooling capacity KW
50HZ/60HZ
-10℃ 3.8
4.6
6.3
7.6
7.5           9 9.1
10.9
13.2
15.8
16.1
19.3
19.5
23.4
26.4
31.7
32.2
38.6
39
46.8
52
62.4
-20℃ 1.9
2.3
3.0
3.6
4           4.8 6
7.2
7.1
8.5
8
9.6
13.9
16.7
16.9
20.3
20.8
25
24.4
29.3
30.8
37
-30℃ 1.0
1.2
1.6
1.9
1.9        2.3 2.7
3.2
3.2
3.8
3.8
4.6
6.1
7.3
9.5
11.4
12.1
14.5
14.3
17.1
19
22.8
-35℃ 0.67
0.8
1.04
1.25
1.5        1.8 2.3
2.8
2.8
3.4
3
3.6
4.3
5.2
6.35
7.62
8.3
10
10.1
12.1
13.35
16
HP   3HP 5HP 6HP 8HP 10HP 12HP 15HP 20HP 25HP 30HP 40HP
Evaporator Chilled water(m3/h) -10℃ 0.65  0.79 1.1       1.3 1.3       1.5 1.6        1.9 2.3          2.7 2.8          3.3 3.4           4.1 4.5          5.4 5.6          6.7 6.7           8.1 9           10.8
-20℃ 0.33     0.4 0.52   0.62 0.69   0.83 1.1       1.3 1.23      1.47 1.38      1.65 2.39      2.87 2.85      3.45 3.57        4.3 4.2        5.04 5.3        6.36
-30℃ 0.17   0.21 0.28   0.33 0.33     0.4 0.47   0.55 0.55      0.65 0.65       0.8 1.1          1.3 1.6             2 2.1           2.5 2.46        2.9 3.3          3.9
-35℃ 0.12   0.14 0.18  0.22 0.26   0.31 0.4      0.48 0.48      0.58 0.52      0.62 0.72      0.89 1.1        1.31 1.43      1.72 1.74      2.09 2.3        2.76
Type  shell and tube type/Plate type heat exchanger
inlet/outlet pipe lnch 1" 1" 1" 1" 1-1/2" 1-1/2" 2" 2" 2" 2-1/2" 2-1/2"
Input power KW 3.18 4.86 5.61 7.25 9.4 10.9 13.5 18.8 22.55 28.5 37.5
Max Current A 7.8 12 13.7 18 23 26.5 33 46 55 69 91
power source 3PH~380V/415V~50HZ/60HZ(3PH~200V/220V   50HZ/60HZ)
Refrigerant Type   R404A 
Control External balance thermal expansion valve
Compressor Type  Hermetic scroll ( piston )
Power KW 2.25 3.75 4.5 6 7.5 9 11.3 7.5*2 9.37*2 11.3*2 30
Condenser Type Efficient finned copper tube with aluminum + low noise external rotor fan
Water pump Power KW 0.75 0.75 0.75 0.75 1.1 1.1 1.5 2.2 2.2 4 5.5
Max lift m 20 20 20 20 20 20 20 20 20 25 20
Safety devices ##################################################################################
Dimension Length mm 980 1150 1150 1350 1500 1500 1860 2020 2020 2200 2350
Width mm 520 560 560 680 760 760 850 950 950 1150 1350
Height mm 1170 1215 1215 1530 1660 1660 1900 2000 2000 1980 2000
Net weight Kg 135 165 210 310 450 530 750 835 920 1080 1125
Notes:
1.Rated cooling capacity is based on: chilled water inlet and outlet water temperature 12℃/ 7℃, the cooling air inlet and outlet temperature 30℃/ 35℃
2.Scope of work: chilled water temperature range: -30℃to 35℃; chilled water inlet and outlet temperature difference: 3℃to 8℃.
The ambient temperature of condensation: Not higher than 35℃(non-standard chiller ambient temperature of condensation can reach maximum 55℃, need to order production). 


Features And Advantages of Small Glycol Chiller

  ▪ Temperature selection range: Process chilled water between -30°C and 5°C can be provided (users can choose different unit specifications according to different production needs).

  ▪ High quality Brazed plate/shell and tube as heat exchanger

  ▪ Inlet and outlet water bypass valves are equipped to adjust the water pressure as needed

  ▪ The water tank sight glass allows the water level and water quality to be checked at a glance.

  ▪ Panasonic/Danfoss scroll compressor with environmental friendly R404a refrigerant

  ▪ Simple&easy installation low maintenance cost

  ▪ Chiller equipped with the following safety protections:Overload Protection,Inverse Phase Alarm,High/Low Pressure Alarm,Water Flow,Water Level Indicator,Anti-Freeze Protection


What Are The Main Components Of Small Glycol Chiller For Distillery?

3.1 Compressor

The compressor is the key mover in glycol chiller because it produces pressure variations to stir the refrigerant around.

For Small Glycol Chiller For Distillery , which is with Panasonic /Danfoss brand compressor, using R404a refrigerant,this brand compress is with high refrigeration efficiency,low noise ,energy saving,environmental protection and durability,safety and stability.

Panasonic Compressor


Danfoss Compressor


3.2 Evaporator

The evaporator is a crucial component of glycol chiller system, as it is responsible for extracting heat from the liquid being cooled,it is located between the compressor and the expansion valve. There are three types of evaporators : shell and tube evaporator, 304SS stainless steel plate type evaporator.

SS Plate Type+ Water Tank Evaporator


Shell and Tube Evaporator


3.3 Water Pump

The water pump is designed to increase the pressure and the flow of the chilled water in a closed space.

the water pressure water pump for chiller is about 2 bar , but if you need more higher water pressure , pls tell us when you inquiry .For example ,when you use chillers for cooling bottle blowing machine ,the water pressure for water pump need about 4 bar .

 

Water Pump


High Pressure Water Pump


3.4 Condenser

The condenser for low temperature chiller is equipped with efficient cross-seam fins and female threaded copper tubes for high heat exchange efficiency and good stability.Its function is to cool down the refrigerant steam released from the compressor into a liquid or gas-liquid mixture.

 

Aluminum fin+fan Condenser


3.5 Controller Panel

Tongwei chillers use precision digital temperature controller, it RS485 communication port,which can do remote monitoring and control. Simple operation, low failure rate, high safety factor, easy installation.

Controller Panel


Spare Part for Glycol Chiller


What’s the Difference Between Air-cooled & Water-cooled Glycol Distillery Chillers?

There are two types of glycol distillery chiller: one is air-cooled glycol distillery chiller ,the other is water-cooled glycol distillery chiller ;

Air-cooled glycol distillery chillers use ambient air to dissipate heat from the distillery processes. They are energy-efficient, space-saving, and less maintenance that helps save money.

Water-cooled glycol distillery chillers use water from an external water cooling tower to dissipate heat from the distillery processes. These systems are longer lifespan, Relatively quiet, and more consistent cooling performance than the air-cooled brewery chiller.

   

Air-cooled Distinllery Chiller                        


Water-cooled Distillery Chiller


Air-cooled Distillery Chiller Installation


Air-cooled Distillery Chiller Installation


Should you choose an air-cooled or water-cooled low temperature distillery chiller? Contact Us for help determining the best solution for you.


What is the Difference Between Glycol Scroll Distillery Chiller and Glycol Screw Distllery Chiller?

Glycol Scroll Distillery Chiller                                 Glycol Screw Distillery Chiller

▪ 1hp-60HP                                                              Above 60HP

▪ Danfoss/Panasonic Scroll Compressor                         Hanbell/Bitzer Screw compressor

▪Built with water tank and water pump                          Without water tank and water pump

             

Air Cooled Glycol Scroll Distillery Chiller  

 

              

Air Cooled Glycol Screw Distillery Chiller

 

Water Cooled Glycol Scroll Distillery Chiller        


           

Water Cooled Glycol Screw Distillery Chiller


Why Glycol Is Used for Cooling?

The most commonly used coolant in a chiller is water or a mixture of water-glycol. Glycol-based coolants consist of either ethylene glycol or propylene glycol. The main advantage of glycol coolants is their anti-freeze properties. Pure water freezes at 0 degrees C, while 30% ethylene glycol freezes at -14 degrees C. The low freezing point of glycol mixtures makes them ideal for cooling items that are below the freezing point of water. Although glycol has a lower heat capacity than water (each kilogram of glycol is easier to heat than one kilogram of water), the high temperature difference allows the glycol mixture to dissipate heat more quickly than pure water. The glycol mixtures are more suitable for applications where the chiller must quickly dissipate a large number of heat. In addition to providing excellent heat transfer parameters, glycol tends to discourage algae growth in heat transfer equipment.


Comparison of Ethylene Glycol and Propylene GlycolProperty

Property

Ethylene Glycol

Propylene Glycol

Freeze point depression

More effective  

Less effective  

Heat transfer efficiency/capacity

Better   

Less

Viscosity    

Lower     

Higher 

Flammability

Low

Low

Chemical Oxygen Demand

Low

  Higher

Biodegrading

Degradesin 10-30 days      

Needs more than 20-30 days to degrade

Carcinogenic

No

No

Toxic

High level of acute when taken orally, targets the kidneys

 

Lower level of acute

 

Skin Irritant 

Low      

Low


Ethylene Gycol And Propylene Glycol


How Does A Low Temperature Glycol Chiller Work?

A glycol chiller is composed of a refrigeration component and tubing containing a water-glycol mixture as coolant. Chilled fluid from the refrigeration unit is channeled through the piping associated with a thermal exchanger surrounding a heated process. After absorbing heat from the associated process, the hot coolant is returned to the refrigeration unit for cooling after which the process is repeated.


A glycol chiller consists of a compressor, an evaporator, a condenser, a throttling element, and an electric control system. Let’s see what’s the working principle of a glycol chiller:

Glycol Chiller Working Principle


The Ratio of Water to Glycol to Use

It is important to use the proper ratio of glycol to water mixture in the cooling system depends on the coldest temperature you need during operation, as insufficient glycol can cause the system to freeze, possibly bursting pipes and even destroying the chiller evaporator even may damage the glycol chiller, while too much glycol to a chiller system will result in an inefficient system.


But what’s the best ratio for glycol and water mixtures? Please see below glycol ratio of glycol and water mixtures for the glycol chiller in your cooling process:

Glycol

Water

Water Temperature

16%

84%

0℃

24%

76%

-5℃

32%

68%

-10℃

40%

60%

-15℃

45%

55%

-20℃

50%

50%

-25℃

55%

45%

-30℃


How I Can Choose The Right Low Temperature Chiller For Your Application?

There are four important chiller specifications you need consider when you choose a chiller for your application :the cooling capacity for chiller ,the voltage required for operation, the associated pump horsepower and flow rate (contact us for custom selection), refrigerant, and the evaporator type.


10.1 Air-Cooled Glycol Chiller or Water-Cooled Glycol Chiller

There are two types of glycol chiller: one is air-cooled type, the other one is water-cooled type.

Air Cooled glycol scroll chillers use aluminum fin+fan as condensers that is similar to the “radiators” in a car.They use a fan to force air through the refrigerant coil. Unless they are specifically designed for high ambient conditions, air-cooled condensers need to operate effectively at an ambient temperature of 45℃ or less.

Water Cooled glycol scroll chiller use shell and tube as condensers.The heat enters the condenser water from the refrigerant vapor. The warm condenser water is then pumped to the water cooling tower, where the heat from the process is eventually vented to the atmosphere.


10.2 Calculate Right Cooling Capacity For Chiller

One of the most frequently ask about how we can know the cooling capacity for chillers.  We use KW ,Ton, But/h,Kcal/h to choose chiller cooling capacity :1 KW=860 kcal/h ;  1 TON=3.517 KW;1 KW=3412 Btu/h;


There is also a formula to calculate the cooling capacity for chiller:.

Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-T2)/0.86

Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)

Oversize the chiller by 20% Ideal Size in KW = KW x 1.2

Noted : T1:Incoming Water Temperature (℃)      T2:Required Chilled Water Temperature(℃)    

   

For example, what size of chiller is required to cool 10m³ water from 35°c to 15 °c in 1 hour?

Temperature Differential = 35℃-15℃=20℃

Water Flow Rate = 10 m³/hour

Cooling Capacity in KW = 10 x 20 ÷ 0.86 = 232 KW

Oversize the chiller = 232 x 1.2 = 278.4KW

278.4 kw cooling capacity for chiller is required.


10.3 Power

Different countries and regions have different standards for industrial electricity, the common power supplies are 208-230V, 380-420V,440-480V,50Hz or 60Hz, 3phase.

Such in Philippines ,the power supply is 220V 60HZ 3PH , 380V 60HZ 3PH ,460V 60HZ 3PH;

in Singapore and Malaysia ,the power supply is 415V 50HZ 3PH;

in Mexico ,the power supply is 220V 60HZ 3PH;

In USA ,the power supply is 208V 60HZ 3PH;575V 60HZ 3PH;480V 60HZ 3PH and so on


10.4 Water Pump

When you decide the capacity/tonnage of the chiller, we will recommend you the suitable pump in KW,which standard water pump is about 2 bar .If you need more high water pressure , please us when you inquiry.


10.5 Refrigerant

R22, R410A, R407C, R404A, R134A are optional choices.

R22: good cooling effect, but R22 is considered a powerful greenhouse gas, so it’s forbidden in most countries.

R410A: eco-friendly, R-410A has replaced R-22 as the preferred refrigerant for use in residential and commercial air conditioners in Japan, Europe, and the United States. R-410A operates at higher pressures than other refrigerants.

R407C: a good replacement for R22, good cooling effect.

R404A: suitable for application that requires low temperature(below -10°c).

R134A: a non-flammable gas used primarily as a “high-temperature” refrigerant, suitable for air-cooled chiller working at a high ambient temperature above 50℃.


10.6 Evaporator Choose

Chillers generally have two types of evaporators: one is stainless steel+ water tank evaporator ,the other one is shell and tube evaporator.

Stainless steel plate and tank evaporator, which has a built-in water storage tank for more convenient use,so there’s no need for extra buffer tanks. This is also our standard evaporator for chiller , if you don’t have buffer tank ,we just use this evaporator for your chiller.

Shell and tube type evaporator, which requires an additional water buffer tank to connect .


Shipping Way of Small Glycol Chiller For Distillery

As a professional low temperature glycol chiller supplier &exporter,we have our own shipment forwarder to arrange the shipment .Our chiller machine is with plywood packing,which prevent damage during transportation and meet export standards.There are three ways can delivery your chiller unit :


1. Ship by Air: As the chiller is with compressor ,water pump and fans ,the compressed refrigerant and oil inside the compressor is a dangerous item with the possibility of explosion , so it needs to release the compressed refrigerant before transportation. (It means that water chiller without refrigerant when choosing this shipping way. After the machine arrives at your destination, you need to add refrigerant by local professionals. The airline company also request us to provide many documents to prove that the chiller not a dangerous product. The freight cost by air is very high may be higher than the cost of chiller , So By air for delivery is not the mode of transport recommended to our customer.


2. Ship by Sea: The transportation time is longer than by air , but the freight cost is cheap ,and there is no need to add refrigerant after the equipment arrives at the destination.This shipping way is the most suitable mode of transportation for you to delivery your local port.


3.If you have your own shipment container in your other supplier in China, we can help you delivery the chiller machine to your supplier in any city of China .


Why should you choose Tongwei for your glycol chiller supplier?

▪ Experience you can trust

We have been designing and building water chiller for over 15 years. From air cooled chiller to water cooled chillers and everything in between, we have built chillers for nearly every industry and every application.


▪ Fast Quote

Get a quote for your project today! We typically provide a custom quote within 2 hours.


▪ 24/7 customer service

Believe that we will always be by your side. Whether you have a question or need a quote, there‘s always someone answering the phone 24 hours a day.


▪ Durable and reliable machine

Our products are manufactured from high quality materials and we offer a competitive warranty on all  industrial chillers.



Hot Tags: Small Glycol Chiller For Distillery, China, Manufacturers, Suppliers, Factory, Wholesale, Buy, Made in China, Cheap, Discount, CE, Quality
Related Category
Send Inquiry
Please Feel free to give your inquiry in the form below. We will reply you in 24 hours.
X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept